CORE-17050
Display the shutdown message popup dialog on the current input desktop,
and periodically monitor for any change of the input desktop. When the
latter changes, close the dialog and recreate it on the new input desktop.
In addition, retain the current dialog position and restore it when the
dialog is recreated on the new desktop.
CORE-16123
- NETID: Correct the call when using the "Computer Name Change" in ReactOS.
- WINLOGON: Update the volatile "Hostname" and "Domain" variables from
their non-volatile counterparts.
Co-authored-by: Hermès Bélusca-Maïto <hermes.belusca-maito@reactos.org>
This avoids keeping connections open and reopening them as soon
as the user reopens their session.
This fixes network shared being duplicated each time session
is reopened.
CORE-15012
as documented in "Advanced Windows NT" by Jeffrey M. Richter (Microsoft Press),
and in https://is.muni.cz/el/1433/jaro2010/PB167/um/cv5/undocumented_CreateProcess.pdf .
[INCLUDE][SERVICES][WIN32K:NTUSER] Add an undocumented STARTF_INHERITDESKTOP flag
for the STARTUPINFO::dwFlags structure member, whose purpose is to tell Win32k
that the created handles to the window station and desktop to which the
process is connecting to, can be inherited by its child processes.
It is used when starting interactive services.
Observed via API monitoring on Windows 2003.
- Perform an immediate system shutdown if the timeout is zero, otherwise
display the countdown shutdown dialog.
- Cleanup pShutdownParams->pszMessage as soon as the dialog goes away.
- It actually appears (tested on Windows 2000 and 2003) that sending
WM_CLOSE messages from a user-mode app to the shutdown dialog really
do nothing (and in particular does not cancel the shutdown!), so modify
the code to take this fact into account.
- Use the "%d days" format for timeouts longer than a day.
- Fail if timeout is 10 years or longer.
- TODO: Replace format strings by resources. German WinXP uses "%d days" instead of "%d Tage". We can do better! ;-)
- Replace the winlogon icon by the warning icon.
- Add more space for the main text.
- Move the shutdown time into a separate line to ensure it is always fully visible.
- Add more space for the shutdown message and keep the message empty by default.
- Clean up the resource IDs.
- Replace the UNICODE_STRING usMessage by a PWSTR pszMessage.
- Use the "%02d:%02d:%02d" time format and get rid of the safe string printf because the string will NEVER be longer than 8 characters.
- Rename the timer id constant because it is NOT a resource id.
- Rename variables according to the coding style.