reactos/drivers/base/kdcom/kdcom.c
Dmitry Borisov 222e79232c
[CPORTLIB][NTOS:INBV][KDCOM][FREELDR] Add ComPort library for NEC PC-98 series (#2407)
There are 2 known serial ports:
    COM1 - based on Intel 8251A
    COM2 - National Semiconductor 16550
2020-03-06 19:50:31 +01:00

349 lines
8.3 KiB
C

/*
* COPYRIGHT: GPL, see COPYING in the top level directory
* PROJECT: ReactOS kernel
* FILE: drivers/base/kddll/kdcom.c
* PURPOSE: COM port functions for the kernel debugger.
* PROGRAMMER: Timo Kreuzer (timo.kreuzer@reactos.org)
*/
#include "kddll.h"
#include <cportlib/cportlib.h>
#include <arc/arc.h>
#include <stdio.h>
#include <stdlib.h>
#include <ndk/halfuncs.h>
/* Serial debug connection */
#define DEFAULT_DEBUG_PORT 2 /* COM2 */
#define DEFAULT_DEBUG_COM1_IRQ 4 /* COM1 IRQ */
#define DEFAULT_DEBUG_COM2_IRQ 3 /* COM2 IRQ */
#define DEFAULT_DEBUG_BAUD_RATE 115200 /* 115200 Baud */
#define DEFAULT_BAUD_RATE 19200
#if defined(_M_IX86) || defined(_M_AMD64)
#if defined(SARCH_PC98)
const ULONG BaseArray[] = {0, 0x30, 0x238};
#else
const ULONG BaseArray[] = {0, 0x3F8, 0x2F8, 0x3E8, 0x2E8};
#endif
#elif defined(_M_PPC)
const ULONG BaseArray[] = {0, 0x800003F8};
#elif defined(_M_MIPS)
const ULONG BaseArray[] = {0, 0x80006000, 0x80007000};
#elif defined(_M_ARM)
const ULONG BaseArray[] = {0, 0xF1012000};
#else
#error Unknown architecture
#endif
#define MAX_COM_PORTS (sizeof(BaseArray) / sizeof(BaseArray[0]) - 1)
/* GLOBALS ********************************************************************/
CPPORT KdComPort;
ULONG KdComPortIrq = 0; // Not used at the moment.
#ifdef KDDEBUG
CPPORT KdDebugComPort;
#endif
/* DEBUGGING ******************************************************************/
#ifdef KDDEBUG
ULONG KdpDbgPrint(const char *Format, ...)
{
va_list ap;
int Length;
char* ptr;
CHAR Buffer[512];
va_start(ap, Format);
Length = _vsnprintf(Buffer, sizeof(Buffer), Format, ap);
va_end(ap);
/* Check if we went past the buffer */
if (Length == -1)
{
/* Terminate it if we went over-board */
Buffer[sizeof(Buffer) - 1] = '\n';
/* Put maximum */
Length = sizeof(Buffer);
}
ptr = Buffer;
while (Length--)
{
if (*ptr == '\n')
CpPutByte(&KdDebugComPort, '\r');
CpPutByte(&KdDebugComPort, *ptr++);
}
return 0;
}
#endif
/* FUNCTIONS ******************************************************************/
NTSTATUS
NTAPI
KdD0Transition(VOID)
{
return STATUS_SUCCESS;
}
NTSTATUS
NTAPI
KdD3Transition(VOID)
{
return STATUS_SUCCESS;
}
NTSTATUS
NTAPI
KdSave(IN BOOLEAN SleepTransition)
{
/* Nothing to do on COM ports */
return STATUS_SUCCESS;
}
NTSTATUS
NTAPI
KdRestore(IN BOOLEAN SleepTransition)
{
/* Nothing to do on COM ports */
return STATUS_SUCCESS;
}
NTSTATUS
NTAPI
KdpPortInitialize(IN ULONG ComPortNumber,
IN ULONG ComPortBaudRate)
{
NTSTATUS Status;
KDDBGPRINT("KdpPortInitialize, Port = COM%ld\n", ComPortNumber);
Status = CpInitialize(&KdComPort,
UlongToPtr(BaseArray[ComPortNumber]),
ComPortBaudRate);
if (!NT_SUCCESS(Status))
{
return STATUS_INVALID_PARAMETER;
}
else
{
KdComPortInUse = KdComPort.Address;
return STATUS_SUCCESS;
}
}
/******************************************************************************
* \name KdDebuggerInitialize0
* \brief Phase 0 initialization.
* \param [opt] LoaderBlock Pointer to the Loader parameter block. Can be NULL.
* \return Status
*/
NTSTATUS
NTAPI
KdDebuggerInitialize0(IN PLOADER_PARAMETER_BLOCK LoaderBlock OPTIONAL)
{
ULONG ComPortNumber = DEFAULT_DEBUG_PORT;
ULONG ComPortBaudRate = DEFAULT_DEBUG_BAUD_RATE;
PCHAR CommandLine, PortString, BaudString, IrqString;
ULONG Value;
/* Check if we have a LoaderBlock */
if (LoaderBlock)
{
/* Get the Command Line */
CommandLine = LoaderBlock->LoadOptions;
/* Upcase it */
_strupr(CommandLine);
/* Get the port and baud rate */
PortString = strstr(CommandLine, "DEBUGPORT");
BaudString = strstr(CommandLine, "BAUDRATE");
IrqString = strstr(CommandLine, "IRQ");
/* Check if we got the /DEBUGPORT parameter */
if (PortString)
{
/* Move past the actual string, to reach the port*/
PortString += strlen("DEBUGPORT");
/* Now get past any spaces and skip the equal sign */
while (*PortString == ' ') PortString++;
PortString++;
/* Do we have a serial port? */
if (strncmp(PortString, "COM", 3) != 0)
{
return STATUS_INVALID_PARAMETER;
}
/* Check for a valid Serial Port */
PortString += 3;
Value = atol(PortString);
if (Value >= sizeof(BaseArray) / sizeof(BaseArray[0]))
{
return STATUS_INVALID_PARAMETER;
}
/* Set the port to use */
ComPortNumber = Value;
}
/* Check if we got a baud rate */
if (BaudString)
{
/* Move past the actual string, to reach the rate */
BaudString += strlen("BAUDRATE");
/* Now get past any spaces */
while (*BaudString == ' ') BaudString++;
/* And make sure we have a rate */
if (*BaudString)
{
/* Read and set it */
Value = atol(BaudString + 1);
if (Value) ComPortBaudRate = Value;
}
}
/* Check Serial Port Settings [IRQ] */
if (IrqString)
{
/* Move past the actual string, to reach the rate */
IrqString += strlen("IRQ");
/* Now get past any spaces */
while (*IrqString == ' ') IrqString++;
/* And make sure we have an IRQ */
if (*IrqString)
{
/* Read and set it */
Value = atol(IrqString + 1);
if (Value) KdComPortIrq = Value;
}
}
}
#ifdef KDDEBUG
/*
* Try to find a free COM port and use it as the KD debugging port.
* NOTE: Inspired by reactos/boot/freeldr/freeldr/comm/rs232.c, Rs232PortInitialize(...)
*/
{
/*
* Start enumerating COM ports from the last one to the first one,
* and break when we find a valid port.
* If we reach the first element of the list, the invalid COM port,
* then it means that no valid port was found.
*/
ULONG ComPort;
for (ComPort = MAX_COM_PORTS; ComPort > 0; ComPort--)
{
/* Check if the port exist; skip the KD port */
if ((ComPort != ComPortNumber) && CpDoesPortExist(UlongToPtr(BaseArray[ComPort])))
break;
}
if (ComPort != 0)
CpInitialize(&KdDebugComPort, UlongToPtr(BaseArray[ComPort]), DEFAULT_BAUD_RATE);
}
#endif
KDDBGPRINT("KdDebuggerInitialize0\n");
/* Initialize the port */
return KdpPortInitialize(ComPortNumber, ComPortBaudRate);
}
/******************************************************************************
* \name KdDebuggerInitialize1
* \brief Phase 1 initialization.
* \param [opt] LoaderBlock Pointer to the Loader parameter block. Can be NULL.
* \return Status
*/
NTSTATUS
NTAPI
KdDebuggerInitialize1(IN PLOADER_PARAMETER_BLOCK LoaderBlock OPTIONAL)
{
return STATUS_SUCCESS;
}
VOID
NTAPI
KdpSendByte(IN UCHAR Byte)
{
/* Send the byte */
CpPutByte(&KdComPort, Byte);
}
KDP_STATUS
NTAPI
KdpPollByte(OUT PUCHAR OutByte)
{
USHORT Status;
/* Poll the byte */
Status = CpGetByte(&KdComPort, OutByte, FALSE, FALSE);
switch (Status)
{
case CP_GET_SUCCESS:
return KDP_PACKET_RECEIVED;
case CP_GET_NODATA:
return KDP_PACKET_TIMEOUT;
case CP_GET_ERROR:
default:
return KDP_PACKET_RESEND;
}
}
KDP_STATUS
NTAPI
KdpReceiveByte(OUT PUCHAR OutByte)
{
USHORT Status;
/* Get the byte */
Status = CpGetByte(&KdComPort, OutByte, TRUE, FALSE);
switch (Status)
{
case CP_GET_SUCCESS:
return KDP_PACKET_RECEIVED;
case CP_GET_NODATA:
return KDP_PACKET_TIMEOUT;
case CP_GET_ERROR:
default:
return KDP_PACKET_RESEND;
}
}
KDP_STATUS
NTAPI
KdpPollBreakIn(VOID)
{
KDP_STATUS KdStatus;
UCHAR Byte;
KdStatus = KdpPollByte(&Byte);
if ((KdStatus == KDP_PACKET_RECEIVED) && (Byte == BREAKIN_PACKET_BYTE))
{
return KDP_PACKET_RECEIVED;
}
return KDP_PACKET_TIMEOUT;
}
/* EOF */