mirror of
https://github.com/reactos/reactos.git
synced 2024-11-18 21:13:52 +00:00
81db5e1da8
Converted from Cantonese to HK-Style Written Chinese. Also assign zh-HK translations to the ReactOS Chinese translation team in the CODEOWNERS file. Reviewed-by: He Yang <1160386205@qq.com> Reviewed-by: Stanislav Motylkov <x86corez@gmail.com> Reviewed-by: Hermès Bélusca-Maïto <hermes.belusca-maito@reactos.org>
185 lines
5.2 KiB
INI
185 lines
5.2 KiB
INI
; SCSI.INF
|
||
;
|
||
; Installation file for SCSI class and SCSI hardware
|
||
;
|
||
[Version]
|
||
Signature = "$Windows NT$"
|
||
;Signature = "$ReactOS$"
|
||
LayoutFile = layout.inf
|
||
Class = SCSIAdapter
|
||
ClassGUID = {4D36E97B-E325-11CE-BFC1-08002BE10318}
|
||
Provider = %ReactOS%
|
||
DriverVer = 11/02/2007,1.1
|
||
|
||
[ClassInstall32.NT]
|
||
AddReg = SCSIClass.NT.AddReg
|
||
|
||
[SCSIClass.NT.AddReg]
|
||
HKR, , , 0, %SCSIClassName%
|
||
HKR, , Icon, 0, "-10"
|
||
;HKR, , Installer32, 0, "syssetup.dll,ScsiClassInstaller"
|
||
|
||
[DestinationDirs]
|
||
DefaultDestDir = 12
|
||
|
||
[Manufacturer]
|
||
%GenericMfg% = GenericMfg
|
||
|
||
[GenericMfg]
|
||
%GEN_SCSIADAPTER.DeviceDesc% = NO_DRV,,GEN_SCSIADAPTER
|
||
%PCI\VEN_104B&CC_0100.DeviceDesc% = BusLogic_Inst,PCI\VEN_104B&CC_0100
|
||
|
||
;----------------------------- ScsiPort Driver ----------------------------
|
||
|
||
[Scsiport_CopyFiles.NT]
|
||
scsiport.sys
|
||
|
||
[Scsiport_Service_Inst]
|
||
ServiceType = 4
|
||
StartType = 0
|
||
ErrorControl = 0
|
||
ServiceBinary = %12%\scsiport.sys
|
||
LoadOrderGroup = SCSI Port
|
||
|
||
;---------------------------- NO DRIVER REQ -----------------------------
|
||
|
||
[NO_DRV]
|
||
|
||
[NO_DRV.Services]
|
||
AddService = , 0x00000002
|
||
|
||
;----------------------------- BusLogic Driver ----------------------------
|
||
|
||
[BusLogic_Inst.NT]
|
||
CopyFiles = BusLogic_CopyFiles.NT, Scsiport_CopyFiles.NT
|
||
|
||
[BusLogic_CopyFiles.NT]
|
||
buslogic.sys
|
||
|
||
[BusLogic_Inst.NT.Services]
|
||
AddService = BusLogic, 0x00000002, BusLogic_Service_Inst
|
||
AddService = Scsiport, , Scsiport_Service_Inst
|
||
|
||
[BusLogic_Service_Inst]
|
||
ServiceType = 0
|
||
StartType = 0
|
||
ErrorControl = 0
|
||
ServiceBinary = %12%\buslogic.sys
|
||
LoadOrderGroup = SCSI Miniport
|
||
|
||
;--------------------------------- Strings ---------------------------------
|
||
|
||
[Strings]
|
||
ReactOS = "ReactOS Team"
|
||
SCSIClassName = "SCSI and RAID Controllers"
|
||
|
||
GenericMfg = "(Standard SCSI and RAID controllers)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID Host Controller"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Controller"
|
||
|
||
[Strings.0404]
|
||
SCSIClassName = "SCSI / RAID 控制器"
|
||
|
||
GenericMfg = "(標準 SCSI / RAID 控制器)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID 主機控制器"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
|
||
|
||
[Strings.0405]
|
||
SCSIClassName = "SCSI a RAID řadiče"
|
||
|
||
GenericMfg = "(Standardní SCSI a RAID řadiče)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI řadič"
|
||
|
||
[Strings.0407]
|
||
SCSIClassName = "SCSI und RAID Controller"
|
||
|
||
GenericMfg = "(Standard SCSI und RAID Controller)"
|
||
|
||
[Strings.0a]
|
||
ReactOS = "Equipo de ReactOS"
|
||
SCSIClassName = "Controladores SCSI y RAID"
|
||
|
||
GenericMfg = "(Controladores estándar SCSI y RAID)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "Controlador Huésped de SCSI/RAID"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
|
||
|
||
[Strings.040C]
|
||
SCSIClassName = "Contrôleurs SCSI et RAID"
|
||
|
||
GenericMfg = "(Contrôleur standard SCSI et RAID)"
|
||
|
||
[Strings.0411]
|
||
SCSIClassName = "SCSIおよびRAID コントローラ"
|
||
|
||
GenericMfg = "(スタンダード SCSI および RAID コントローラ)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI コントローラ"
|
||
|
||
[Strings.0415]
|
||
ReactOS = "Zespół ReactOS"
|
||
SCSIClassName = "Kontrolery SCSI i RAID"
|
||
GenericMfg = "(Standardowe kontrolery SCSI i RAID)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Kontroler SCSI BusLogic"
|
||
|
||
[Strings.0416]
|
||
SCSIClassName = "Controladores SCSI e RAID"
|
||
|
||
GenericMfg = "(Controladores SCSI e RAID padrão)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
|
||
|
||
[Strings.0418]
|
||
ReactOS = "Echipa ReactOS"
|
||
SCSIClassName = "Dispozitive de control SCSI și RAID"
|
||
GenericMfg = "(dispozitiv standard de control SCSI și RAID)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Dispozitiv de control SCSI BusLogic"
|
||
|
||
[Strings.0419]
|
||
ReactOS = "Команда ReactOS"
|
||
SCSIClassName = "SCSI и RAID контроллеры"
|
||
|
||
GenericMfg = "(Стандартные SCSI и RAID контроллеры)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID хост-контроллер"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
|
||
|
||
[Strings.041B]
|
||
SCSIClassName = "SCSI a RAID radiče"
|
||
|
||
GenericMfg = "(Štandardné SCSI a RAID radiče)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI radič"
|
||
|
||
[Strings.041f]
|
||
ReactOS = "ReactOS Takımı"
|
||
SCSIClassName = "SCSI ve RAID Denetleyicileri"
|
||
|
||
GenericMfg = "(Standart SCSI ve RAID Denetleyicileri)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID Ana Denetleyicisi"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Denetleyicisi"
|
||
|
||
[Strings.0422]
|
||
ReactOS = "Команда ReactOS"
|
||
SCSIClassName = "SCSI і RAID контроллери"
|
||
GenericMfg = "(Стандартні SCSI і RAID контроллери)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
|
||
|
||
[Strings.0427]
|
||
SCSIClassName = "SCSI ir RAID valdikliai"
|
||
|
||
GenericMfg = "(Standartiniai SCSI ir RAID valdikliai)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI valdiklis"
|
||
|
||
[Strings.0804]
|
||
GenericMfg = "(标准 SCSI / RAID 控制器)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
|
||
|
||
[Strings.0816]
|
||
ReactOS = "Equipa ReactOS"
|
||
SCSIClassName = "Controladores SCSI e RAID"
|
||
|
||
GenericMfg = "(Controladores SCSI e RAID padrão)"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
|
||
|
||
[Strings.0C04]
|
||
SCSIClassName = "SCSI / RAID 控制器"
|
||
|
||
GenericMfg = "(標準 SCSI / RAID 控制器)"
|
||
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID 主機控制器"
|
||
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
|