2011-03-30 13:49:47 +00:00
|
|
|
.TH FS 3
|
|
|
|
.SH NAME
|
|
|
|
fs \- file system devices
|
|
|
|
.SH SYNOPSIS
|
|
|
|
.nf
|
|
|
|
.B bind -b #k /dev
|
|
|
|
.sp 0.3v
|
|
|
|
.B /dev/fs
|
|
|
|
.B /dev/fs/ctl
|
|
|
|
.B /dev/fs/...
|
|
|
|
.B /dev/\fInew\fP
|
|
|
|
.fi
|
|
|
|
.SH DESCRIPTION
|
|
|
|
The
|
|
|
|
.I fs
|
|
|
|
driver builds complex disk files out of simpler disk files.
|
|
|
|
Inspired by the Plan 9 file server kernel's configuration strings,
|
|
|
|
it provides device mirroring, partitioning, interleaving, and catenation
|
|
|
|
for disk-based services like
|
|
|
|
.IR venti (8).
|
|
|
|
.PP
|
|
|
|
The device is intended to be bound at
|
|
|
|
.B /dev
|
|
|
|
and initially contains a directory named
|
|
|
|
.BR fs ,
|
|
|
|
which in turn contains a
|
|
|
|
.B ctl
|
|
|
|
file and one file per configured device.
|
|
|
|
.PP
|
|
|
|
Most control messages introduce a new device, here named
|
|
|
|
.IR new .
|
|
|
|
The
|
|
|
|
.I file
|
|
|
|
arguments are interpreted in the name space of the writing process.
|
|
|
|
.PP
|
|
|
|
The device name
|
|
|
|
.I new
|
|
|
|
may be a single filename component (containing no slashes);
|
|
|
|
in this case, the device is created under
|
|
|
|
.BR #k/fs .
|
|
|
|
If
|
|
|
|
.I new
|
|
|
|
instead has the format
|
|
|
|
.IB dir / file,
|
|
|
|
the device is made available at
|
|
|
|
.BI #k/ dir / file.
|
|
|
|
The directory
|
|
|
|
.I dir
|
|
|
|
goes away when the last device on it is removed with the
|
|
|
|
.B del
|
|
|
|
control message,
|
|
|
|
but
|
|
|
|
.B #k/fs
|
|
|
|
will never be removed.
|
|
|
|
.TF "del \fIold
|
|
|
|
.PD
|
|
|
|
.TP
|
|
|
|
.BI cat " new files" \fR...
|
|
|
|
The device
|
|
|
|
.I new
|
|
|
|
corresponds to the catenation of
|
|
|
|
.IR files .
|
|
|
|
.TP
|
|
|
|
.BI inter " new files" \fR...
|
|
|
|
The device
|
|
|
|
.I new
|
|
|
|
corresponds to the block interleaving of
|
|
|
|
.IR files ;
|
|
|
|
an 8192-byte block size is assumed.
|
|
|
|
.TP
|
|
|
|
.BI mirror " new files" \fR...
|
|
|
|
The device
|
|
|
|
.I new
|
|
|
|
corresponds to a RAID-1-like mirroring of
|
|
|
|
.IR files .
|
|
|
|
Writes to
|
|
|
|
.BI new
|
|
|
|
are handled by sequentially writing the same data to the
|
|
|
|
.I files
|
|
|
|
from right to left (the reverse of
|
|
|
|
the order in the control message).
|
|
|
|
A failed write causes an eventual error return
|
|
|
|
but does not prevent the rest of the writes
|
|
|
|
to the other devices of the mirror set.
|
|
|
|
Reads from
|
|
|
|
.BI new
|
|
|
|
are handled by sequentially reading from the
|
|
|
|
.I files
|
|
|
|
from left to right until one succeeds.
|
|
|
|
The length of the mirror device is the minimum of the lengths of the
|
|
|
|
.IR files .
|
|
|
|
.TP
|
|
|
|
.BI part " new file offset length"
|
|
|
|
.TP
|
|
|
|
.BI part " new offset end
|
|
|
|
In the first form,
|
|
|
|
the device
|
|
|
|
.I new
|
|
|
|
corresponds to the
|
|
|
|
.I length
|
|
|
|
units starting at
|
|
|
|
.I offset
|
|
|
|
in
|
|
|
|
.IR file .
|
|
|
|
If
|
|
|
|
.IR offset + length
|
|
|
|
reaches past the end of
|
|
|
|
.IR file ,
|
|
|
|
.I length
|
|
|
|
is silently reduced to fit.
|
|
|
|
Units are bytes.
|
|
|
|
In the second form,
|
|
|
|
a previous
|
|
|
|
.B disk
|
|
|
|
request must have defined the source
|
|
|
|
.I file
|
|
|
|
for further requests and the end of the device
|
|
|
|
is determined by the
|
|
|
|
.I end
|
|
|
|
offset in the source file, and not by the device
|
|
|
|
length. Units are as defined in the previous
|
|
|
|
.B disk
|
|
|
|
request. This form is accepted for compatibility with
|
|
|
|
.IR fdisk
|
|
|
|
(in
|
|
|
|
.IR prep (8))
|
|
|
|
and
|
|
|
|
.IR sd (3)
|
|
|
|
devices.
|
|
|
|
.TP
|
|
|
|
.BI del " old
|
|
|
|
Removes the device named
|
|
|
|
.IR old .
|
|
|
|
The device will still be seen while in use.
|
|
|
|
Further I/O attempts will fail with an error indication stating that
|
|
|
|
the device is gone.
|
|
|
|
When
|
|
|
|
.I old
|
|
|
|
is
|
|
|
|
.IB dir /*\fR,
|
|
|
|
all devices under
|
|
|
|
.I dir
|
|
|
|
are removed.
|
|
|
|
.TP
|
|
|
|
.BI disk " dir [ n file ]
|
|
|
|
makes
|
|
|
|
.I dir
|
|
|
|
implicit in new device names (i.e., it makes
|
|
|
|
.I new
|
|
|
|
mean
|
|
|
|
.IB dir / new
|
|
|
|
by default).
|
|
|
|
Optional argument
|
|
|
|
.I n
|
|
|
|
specifies the default unit (sector) size in bytes and the default source
|
|
|
|
.I file
|
|
|
|
for further partition devices.
|
|
|
|
Default values are restored when the control file is closed.
|
|
|
|
.TP
|
2012-07-05 17:17:03 +00:00
|
|
|
.BI crypt " new file key"
|
|
|
|
The device
|
|
|
|
.I new
|
|
|
|
corresponds to a AES-encrypted partition
|
|
|
|
.I file
|
|
|
|
encrypted with
|
|
|
|
.I key (see
|
|
|
|
.IR cryptsetup (8)).
|
|
|
|
.TP
|
2011-03-30 13:49:47 +00:00
|
|
|
.B clear
|
|
|
|
Discard all
|
|
|
|
.I fs
|
|
|
|
device definitions.
|
|
|
|
.PD
|
|
|
|
.LP
|
|
|
|
If the variable
|
|
|
|
.B fsconfig
|
|
|
|
is set in
|
|
|
|
.IR plan9.ini (8),
|
|
|
|
.I fs
|
|
|
|
will read its configuration from the file
|
|
|
|
.B $fsconfig
|
|
|
|
on the first attach.
|
|
|
|
This is useful when the machine boots from a local file server that uses
|
|
|
|
.IR fs .
|
|
|
|
.SH EXAMPLES
|
|
|
|
Use a previously partitioned disk,
|
|
|
|
.BR /dev/sdC0 ,
|
|
|
|
making
|
|
|
|
partition files available under
|
|
|
|
.BR /dev/sdC0parts :
|
|
|
|
.IP
|
|
|
|
.EX
|
|
|
|
{
|
|
|
|
echo disk sdC0parts 512 /dev/sdC0/data
|
|
|
|
disk/fdisk -p /dev/sdC0/data
|
|
|
|
# now create plan 9 partitions
|
|
|
|
echo disk sdC0parts 512 /dev/sdC0parts/plan9
|
|
|
|
disk/prep -p /dev/sdC0parts/plan9
|
|
|
|
} > /dev/fs/ctl
|
|
|
|
.EE
|
|
|
|
.LP
|
|
|
|
Mirror the two disks
|
|
|
|
.B /dev/sdC0/data
|
|
|
|
and
|
|
|
|
.B /dev/sdD0/data
|
|
|
|
as
|
|
|
|
.BR /dev/fs/m0 ;
|
|
|
|
similarly, mirror
|
|
|
|
.B /dev/sdC1/data
|
|
|
|
and
|
|
|
|
.B /dev/sdD1/data
|
|
|
|
as
|
|
|
|
.BR /dev/fs/m1 :
|
|
|
|
.IP
|
|
|
|
.EX
|
|
|
|
echo mirror m0 /dev/sdC0/data /dev/sdD0/data >/dev/fs/ctl
|
|
|
|
echo mirror m1 /dev/sdC1/data /dev/sdD1/data >/dev/fs/ctl
|
|
|
|
.EE
|
|
|
|
.LP
|
|
|
|
Interleave the two mirrored disks to create
|
|
|
|
.BR /dev/fs/data :
|
|
|
|
.IP
|
|
|
|
.EX
|
|
|
|
echo inter data /dev/fs/m0 /dev/fs/m1 >/dev/fs/ctl
|
|
|
|
.EE
|
|
|
|
.LP
|
|
|
|
Run
|
2015-08-21 17:51:03 +00:00
|
|
|
.IR hjfs (4)
|
2011-03-30 13:49:47 +00:00
|
|
|
on the interleaved device:
|
|
|
|
.IP
|
|
|
|
.EX
|
2015-08-21 17:51:03 +00:00
|
|
|
hjfs -f /dev/fs/data
|
2011-03-30 13:49:47 +00:00
|
|
|
.EE
|
|
|
|
.LP
|
|
|
|
Save the configuration:
|
|
|
|
.IP
|
|
|
|
.EX
|
|
|
|
cp /dev/fs/ctl /dev/fd0disk
|
|
|
|
.EE
|
|
|
|
.LP
|
|
|
|
To load the configuration automatically at boot time,
|
|
|
|
add this to
|
|
|
|
.IR plan9.ini :
|
|
|
|
.IP
|
|
|
|
.EX
|
|
|
|
fsconfig=/dev/fd0disk
|
|
|
|
.EE
|
|
|
|
.SH "SEE ALSO"
|
|
|
|
.I read
|
|
|
|
in
|
|
|
|
.IR cat (1),
|
|
|
|
.IR dd (1),
|
|
|
|
.IR sd (3),
|
|
|
|
.IR fs (8),
|
|
|
|
.IR plan9.ini (8),
|
|
|
|
.IR prep (8),
|
|
|
|
.IR venti (8)
|
|
|
|
.SH SOURCE
|
|
|
|
.B /sys/src/9/port/devfs.c
|
|
|
|
.SH BUGS
|
|
|
|
Mirrors are RAID-like but not RAID.
|
|
|
|
There is no fancy recovery mechanism and
|
|
|
|
no automatic initial copying from a master drive to its mirror drives.
|
|
|
|
.PP
|
|
|
|
Each
|
|
|
|
.I write
|
|
|
|
system call on
|
|
|
|
.B ctl
|
|
|
|