reactos/win32ss/user/ntuser/shutdown.c
Thamatip Chitpong 90ed686209
[NTUSER] Use UserHMGetHandle macro (#6244)
Use UserHMGetHandle macro everywhere instead of obj->head.h for consistency.
2024-01-05 07:16:44 +07:00

335 lines
9.6 KiB
C

/*
* COPYRIGHT: See COPYING in the top level directory
* PROJECT: ReactOS Win32k subsystem
* PURPOSE: Shutdown routines
* FILE: win32ss/user/ntuser/shutdown.c
* PROGRAMER: Hermes Belusca
*/
#include <win32k.h>
DBG_DEFAULT_CHANNEL(UserShutdown);
/* Our local copy of shutdown flags */
static ULONG gdwShutdownFlags = 0;
/*
* Based on CSRSS and described in pages 1115 - 1118 "Windows Internals, Fifth Edition".
* CSRSS sends WM_CLIENTSHUTDOWN messages to top-level windows, and it is our job
* to send WM_QUERYENDSESSION / WM_ENDSESSION messages in response.
*/
LRESULT
IntClientShutdown(IN PWND pWindow,
IN WPARAM wParam,
IN LPARAM lParam)
{
LPARAM lParams;
BOOL KillTimers;
INT i;
LRESULT lResult = MCSR_GOODFORSHUTDOWN;
HWND *List;
KillTimers = wParam & MCS_ENDSESSION ? TRUE : FALSE;
lParams = lParam & (ENDSESSION_LOGOFF | ENDSESSION_CRITICAL | ENDSESSION_CLOSEAPP);
/* First, send end sessions to children */
List = IntWinListChildren(pWindow);
if (List)
{
for (i = 0; List[i]; i++)
{
PWND WndChild;
if (!(WndChild = UserGetWindowObject(List[i])))
continue;
if (wParam & MCS_QUERYENDSESSION)
{
if (!co_IntSendMessage(UserHMGetHandle(WndChild), WM_QUERYENDSESSION, 0, lParams))
{
lResult = MCSR_DONOTSHUTDOWN;
break;
}
}
else
{
co_IntSendMessage(UserHMGetHandle(WndChild), WM_ENDSESSION, KillTimers, lParams);
if (KillTimers)
{
DestroyTimersForWindow(WndChild->head.pti, WndChild);
}
lResult = MCSR_SHUTDOWNFINISHED;
}
}
ExFreePoolWithTag(List, USERTAG_WINDOWLIST);
if (lResult == MCSR_DONOTSHUTDOWN)
return lResult;
}
/* Send to the caller */
if (wParam & MCS_QUERYENDSESSION)
{
if (!co_IntSendMessage(UserHMGetHandle(pWindow), WM_QUERYENDSESSION, 0, lParams))
{
lResult = MCSR_DONOTSHUTDOWN;
}
}
else
{
co_IntSendMessage(UserHMGetHandle(pWindow), WM_ENDSESSION, KillTimers, lParams);
if (KillTimers)
{
DestroyTimersForWindow(pWindow->head.pti, pWindow);
}
lResult = MCSR_SHUTDOWNFINISHED;
}
return lResult;
}
BOOLEAN
HasPrivilege(IN PPRIVILEGE_SET Privilege)
{
BOOLEAN Result;
SECURITY_SUBJECT_CONTEXT SubjectContext;
/* Capture and lock the security subject context */
SeCaptureSubjectContext(&SubjectContext);
SeLockSubjectContext(&SubjectContext);
/* Do privilege check */
Result = SePrivilegeCheck(Privilege, &SubjectContext, UserMode);
/* Audit the privilege */
#if 0
SePrivilegeObjectAuditAlarm(NULL,
&SubjectContext,
0,
Privilege,
Result,
UserMode);
#endif
/* Unlock and release the security subject context and return */
SeUnlockSubjectContext(&SubjectContext);
SeReleaseSubjectContext(&SubjectContext);
return Result;
}
BOOL
NotifyLogon(IN HWND hWndSta,
IN PLUID CallerLuid,
IN ULONG Flags,
IN NTSTATUS ShutdownStatus)
{
// LUID SystemLuid = SYSTEM_LUID;
ULONG Notif, Param;
ERR("NotifyLogon(0x%lx, 0x%lx)\n", Flags, ShutdownStatus);
/* If no Winlogon notifications are needed, just return */
if (Flags & EWX_NONOTIFY)
return FALSE;
/* In case we cancelled the shutdown...*/
if (Flags & EWX_SHUTDOWN_CANCELED)
{
/* ... send a LN_LOGOFF_CANCELED to Winlogon with the real cancel status... */
Notif = LN_LOGOFF_CANCELED;
Param = ShutdownStatus;
}
else
{
/* ... otherwise it's a real logoff. Send the shutdown flags in that case. */
Notif = LN_LOGOFF;
Param = Flags;
}
// FIXME: At the moment, always send the notifications... In real world some checks are done.
// if (hwndSAS && ( (Flags & EWX_SHUTDOWN) || RtlEqualLuid(CallerLuid, &SystemLuid)) )
if (hwndSAS)
{
TRACE("\tSending %s message to Winlogon\n", Notif == LN_LOGOFF ? "LN_LOGOFF" : "LN_LOGOFF_CANCELED");
UserPostMessage(hwndSAS, WM_LOGONNOTIFY, Notif, (LPARAM)Param);
return TRUE;
}
else
{
ERR("hwndSAS == NULL\n");
}
return FALSE;
}
NTSTATUS
UserInitiateShutdown(IN PETHREAD Thread,
IN OUT PULONG pFlags)
{
NTSTATUS Status;
ULONG Flags = *pFlags;
LUID CallerLuid;
LUID SystemLuid = SYSTEM_LUID;
static PRIVILEGE_SET ShutdownPrivilege =
{
1, PRIVILEGE_SET_ALL_NECESSARY,
{ {{SE_SHUTDOWN_PRIVILEGE, 0}, 0} }
};
PPROCESSINFO ppi;
TRACE("UserInitiateShutdown\n");
/* Get the caller's LUID */
Status = GetProcessLuid(Thread, NULL, &CallerLuid);
if (!NT_SUCCESS(Status))
{
ERR("UserInitiateShutdown: GetProcessLuid failed\n");
return Status;
}
/*
* Check if this is the System LUID, and adjust flags if needed.
* In particular, be sure there is no EWX_CALLER_SYSTEM flag
* spuriously set (could be the sign of malicous app!).
*/
if (RtlEqualLuid(&CallerLuid, &SystemLuid))
Flags |= EWX_CALLER_SYSTEM;
else
Flags &= ~EWX_CALLER_SYSTEM;
*pFlags = Flags;
/* Retrieve the Win32 process info */
ppi = PsGetProcessWin32Process(PsGetThreadProcess(Thread));
if (ppi == NULL)
{
ERR("UserInitiateShutdown: Failed to get win32 thread!\n");
return STATUS_INVALID_HANDLE;
}
/* If the caller is not Winlogon, do some security checks */
if (PsGetThreadProcessId(Thread) != gpidLogon)
{
/*
* Here also, be sure there is no EWX_CALLER_WINLOGON flag
* spuriously set (could be the sign of malicous app!).
*/
Flags &= ~EWX_CALLER_WINLOGON;
*pFlags = Flags;
/* Check whether the current process is attached to a window station */
if (ppi->prpwinsta == NULL)
{
ERR("UserInitiateShutdown: Process is not attached to a desktop\n");
return STATUS_INVALID_HANDLE;
}
/* Check whether the window station of the current process can send exit requests */
if (!RtlAreAllAccessesGranted(ppi->amwinsta, WINSTA_EXITWINDOWS))
{
ERR("UserInitiateShutdown: Caller doesn't have the rights to shutdown\n");
return STATUS_ACCESS_DENIED;
}
/*
* NOTE: USERSRV automatically adds the shutdown flag when we poweroff or reboot.
*
* If the caller wants to shutdown / reboot / power-off...
*/
if (Flags & EWX_SHUTDOWN)
{
/* ... check whether it has shutdown privilege */
if (!HasPrivilege(&ShutdownPrivilege))
{
ERR("UserInitiateShutdown: Caller doesn't have the rights to shutdown\n");
return STATUS_PRIVILEGE_NOT_HELD;
}
}
else
{
/*
* ... but if it just wants to log-off, in case its
* window station is a non-IO one, fail the call.
*/
if (ppi->prpwinsta->Flags & WSS_NOIO)
{
ERR("UserInitiateShutdown: Caller doesn't have the rights to logoff\n");
return STATUS_INVALID_DEVICE_REQUEST;
}
}
}
/* If the caller is not Winlogon, possibly notify it to perform the real shutdown */
if (PsGetThreadProcessId(Thread) != gpidLogon)
{
// FIXME: HACK!! Do more checks!!
TRACE("UserInitiateShutdown: Notify Winlogon for shutdown\n");
NotifyLogon(hwndSAS, &CallerLuid, Flags, STATUS_SUCCESS);
return STATUS_PENDING;
}
// If we reach this point, that means it's Winlogon that triggered the shutdown.
TRACE("UserInitiateShutdown: Winlogon is doing a shutdown\n");
/*
* Update and save the shutdown flags globally for renotifying
* Winlogon if needed, when calling EndShutdown.
*/
Flags |= EWX_CALLER_WINLOGON; // Winlogon is doing a shutdown, be sure the internal flag is set.
*pFlags = Flags;
/* Save the shutdown flags now */
gdwShutdownFlags = Flags;
return STATUS_SUCCESS;
}
NTSTATUS
UserEndShutdown(IN PETHREAD Thread,
IN NTSTATUS ShutdownStatus)
{
NTSTATUS Status;
ULONG Flags;
LUID CallerLuid;
TRACE("UserEndShutdown called\n");
/*
* FIXME: Some cleanup should be done when shutdown succeeds,
* and some reset should be done when shutdown is cancelled.
*/
//STUB;
Status = GetProcessLuid(Thread, NULL, &CallerLuid);
if (!NT_SUCCESS(Status))
{
ERR("UserEndShutdown: GetProcessLuid failed\n");
return Status;
}
/* Copy the global flags because we're going to modify them for our purposes */
Flags = gdwShutdownFlags;
if (NT_SUCCESS(ShutdownStatus))
{
/* Just report success, and keep the shutdown flags as they are */
ShutdownStatus = STATUS_SUCCESS;
}
else
{
/* Report the status to Winlogon and say that we cancel the shutdown */
Flags |= EWX_SHUTDOWN_CANCELED;
// FIXME: Should we reset gdwShutdownFlags to 0 ??
}
TRACE("UserEndShutdown: Notify Winlogon for end of shutdown\n");
NotifyLogon(hwndSAS, &CallerLuid, Flags, ShutdownStatus);
/* Always return success */
return STATUS_SUCCESS;
}
/* EOF */