mirror of
https://github.com/reactos/reactos.git
synced 2024-06-29 01:12:06 +00:00
135 lines
4.9 KiB
C
135 lines
4.9 KiB
C
#pragma once
|
|
|
|
/*
|
|
* usr/include/linux/lp.h c.1991-1992 James Wiegand
|
|
* many modifications copyright (C) 1992 Michael K. Johnson
|
|
* Interrupt support added 1993 Nigel Gamble
|
|
*/
|
|
|
|
/*
|
|
* Per POSIX guidelines, this module reserves the LP and lp prefixes
|
|
* These are the lp_table[minor].flags flags...
|
|
*/
|
|
#define LP_EXIST 0x0001
|
|
#define LP_SELEC 0x0002
|
|
#define LP_BUSY 0x0004
|
|
#define LP_OFFL 0x0008
|
|
#define LP_NOPA 0x0010
|
|
#define LP_ERR 0x0020
|
|
#define LP_ABORT 0x0040
|
|
#define LP_CAREFUL 0x0080
|
|
#define LP_ABORTOPEN 0x0100
|
|
|
|
/* timeout for each character. This is relative to bus cycles -- it
|
|
* is the count in a busy loop. THIS IS THE VALUE TO CHANGE if you
|
|
* have extremely slow printing, or if the machine seems to slow down
|
|
* a lot when you print. If you have slow printing, increase this
|
|
* number and recompile, and if your system gets bogged down, decrease
|
|
* this number. This can be changed with the tunelp(8) command as well.
|
|
*/
|
|
|
|
#define LP_INIT_CHAR 1000
|
|
|
|
/* The parallel port specs apparently say that there needs to be
|
|
* a .5usec wait before and after the strobe. Since there are wildly
|
|
* different computers running linux, I can't come up with a perfect
|
|
* value, but since it worked well on most printers before without,
|
|
* I'll initialize it to 0.
|
|
*/
|
|
|
|
#define LP_INIT_WAIT 0
|
|
|
|
/* This is the amount of time that the driver waits for the printer to
|
|
* catch up when the printer's buffer appears to be filled. If you
|
|
* want to tune this and have a fast printer (i.e. HPIIIP), decrease
|
|
* this number, and if you have a slow printer, increase this number.
|
|
* This is in hundredths of a second, the default 2 being .05 second.
|
|
* Or use the tunelp(8) command, which is especially nice if you want
|
|
* change back and forth between character and graphics printing, which
|
|
* are wildly different...
|
|
*/
|
|
|
|
#define LP_INIT_TIME 2
|
|
|
|
/* IOCTL numbers */
|
|
#define LPCHAR 0x0601 /* corresponds to LP_INIT_CHAR */
|
|
#define LPTIME 0x0602 /* corresponds to LP_INIT_TIME */
|
|
#define LPABORT 0x0604 /* call with TRUE arg to abort on error,
|
|
FALSE to retry. Default is retry. */
|
|
#define LPSETIRQ 0x0605 /* call with new IRQ number,
|
|
or 0 for polling (no IRQ) */
|
|
#define LPGETIRQ 0x0606 /* get the current IRQ number */
|
|
#define LPWAIT 0x0608 /* corresponds to LP_INIT_WAIT */
|
|
#define LPCAREFUL 0x0609 /* call with TRUE arg to require out-of-paper, off-
|
|
line, and error indicators good on all writes,
|
|
FALSE to ignore them. Default is ignore. */
|
|
#define LPABORTOPEN 0x060a /* call with TRUE arg to abort open() on error,
|
|
FALSE to ignore error. Default is ignore. */
|
|
#define LPGETSTATUS 0x060b /* return LP_S(minor) */
|
|
#define LPRESET 0x060c /* reset printer */
|
|
|
|
/* timeout for printing a timeout, in jiffies (100ths of a second).
|
|
This is also used for re-checking error conditions if LP_ABORT is
|
|
not set. This is the default behavior. */
|
|
|
|
#define LP_TIMEOUT_INTERRUPT (60 * HZ)
|
|
#define LP_TIMEOUT_POLLED (10 * HZ)
|
|
|
|
#if 0
|
|
#define LP_B(minor) lp_table[(minor)].base /* IO address */
|
|
#define LP_F(minor) lp_table[(minor)].flags /* flags for busy, etc. */
|
|
#define LP_S(minor) inb_p(LP_B((minor)) + 1) /* status port */
|
|
#define LP_C(minor) (lp_table[(minor)].base + 2) /* control port */
|
|
#define LP_CHAR(minor) lp_table[(minor)].chars /* busy timeout */
|
|
#define LP_TIME(minor) lp_table[(minor)].time /* wait time */
|
|
#define LP_WAIT(minor) lp_table[(minor)].wait /* strobe wait */
|
|
#define LP_IRQ(minor) lp_table[(minor)].irq /* interrupt # */
|
|
/* 0 means polled */
|
|
#endif
|
|
|
|
#define LP_BUFFER_SIZE 256
|
|
|
|
|
|
/*
|
|
* The following constants describe the various signals of the printer port
|
|
* hardware. Note that the hardware inverts some signals and that some
|
|
* signals are active low. An example is LP_STROBE, which must be programmed
|
|
* with 1 for being active and 0 for being inactive, because the strobe signal
|
|
* gets inverted, but it is also active low.
|
|
*/
|
|
|
|
/*
|
|
* bit defines for 8255 status port
|
|
* base + 1
|
|
* accessed with LP_S(minor), which gets the byte...
|
|
*/
|
|
#define LP_PBUSY 0x80 /* inverted input, active high */
|
|
#define LP_PACK 0x40 /* unchanged input, active low */
|
|
#define LP_POUTPA 0x20 /* unchanged input, active high */
|
|
#define LP_PSELECD 0x10 /* unchanged input, active high */
|
|
#define LP_PERRORP 0x08 /* unchanged input, active low */
|
|
|
|
/*
|
|
* defines for 8255 control port
|
|
* base + 2
|
|
* accessed with LP_C(minor)
|
|
*/
|
|
#define LP_PINTEN 0x10
|
|
#define LP_PSELECP 0x08 /* inverted output, active low */
|
|
#define LP_PINITP 0x04 /* unchanged output, active low */
|
|
#define LP_PAUTOLF 0x02 /* inverted output, active low */
|
|
#define LP_PSTROBE 0x01 /* inverted output, active low */
|
|
|
|
/*
|
|
* the value written to ports to test existence. PC-style ports will
|
|
* return the value written. AT-style ports will return 0. so why not
|
|
* make them the same ?
|
|
*/
|
|
#define LP_DUMMY 0x00
|
|
|
|
/*
|
|
* This is the port delay time. Your mileage may vary.
|
|
* It is used only in the lp_init() routine.
|
|
*/
|
|
#define LP_DELAY 150000
|