reactos/media/inf/scsi.inf
Colin Finck 950c86fb4c Fix remaining text file line endings in the tree. (#18)
Based on https://stackoverflow.com/a/1511273

Also enforce CRLF for all *.xml files in our tree, because they are distributed with ReactOS.
2017-10-06 15:00:36 +02:00

148 lines
4 KiB
INI
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

; SCSI.INF
;
; Installation file for SCSI class and SCSI hardware
;
[Version]
Signature = "$Windows NT$"
;Signature = "$ReactOS$"
LayoutFile = layout.inf
Class = SCSIAdapter
ClassGUID = {4D36E97B-E325-11CE-BFC1-08002BE10318}
Provider = %ReactOS%
DriverVer = 11/2/2007,1.1
[ClassInstall32.NT]
AddReg = SCSIClass.NT.AddReg
[SCSIClass.NT.AddReg]
HKR, , , 0, %SCSIClassName%
HKR, , Icon, 0, "-10"
;HKR, , Installer32, 0, "syssetup.dll,ScsiClassInstaller"
[DestinationDirs]
DefaultDestDir = 12
[Manufacturer]
%GenericMfg% = GenericMfg
[GenericMfg]
%PCI\VEN_104B&CC_0100.DeviceDesc% = BusLogic_Inst,PCI\VEN_104B&CC_0100
;----------------------------- ScsiPort Driver ----------------------------
[Scsiport_CopyFiles.NT]
scsiport.sys
[Scsiport_Service_Inst]
ServiceType = 4
StartType = 0
ErrorControl = 0
ServiceBinary = %12%\scsiport.sys
LoadOrderGroup = SCSI Port
;----------------------------- BusLogic Driver ----------------------------
[BusLogic_Inst.NT]
CopyFiles = BusLogic_CopyFiles.NT, Scsiport_CopyFiles.NT
[BusLogic_CopyFiles.NT]
buslogic.sys
[BusLogic_Inst.NT.Services]
AddService = BusLogic, 0x00000002, BusLogic_Service_Inst
AddService = Scsiport, , Scsiport_Service_Inst
[BusLogic_Service_Inst]
ServiceType = 0
StartType = 0
ErrorControl = 0
ServiceBinary = %12%\buslogic.sys
LoadOrderGroup = SCSI Miniport
;--------------------------------- Strings ---------------------------------
[Strings]
ReactOS = "ReactOS Team"
SCSIClassName = "SCSI and RAID Controllers"
GenericMfg = "(Standard SCSI and RAID controllers)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Controller"
[Strings.0405]
SCSIClassName = "SCSI a RAID řadiče"
GenericMfg = "(Standardní SCSI a RAID řadiče)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI řadič"
[Strings.0407]
SCSIClassName = "SCSI und RAID Controller"
GenericMfg = "(Standard SCSI und RAID Controller)"
[Strings.0a]
ReactOS = "Equipo de ReactOS"
SCSIClassName = "Controladoras SCSI y RAID"
GenericMfg = "(Controladoras estándar SCSI y RAID)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Controladora SCSI BusLogic"
[Strings.040C]
SCSIClassName = "Contrôleurs SCSI et RAID"
GenericMfg = "(Contrôleur standard SCSI et RAID)"
[Strings.0411]
SCSIClassName = "SCSIおよびRAID コントローラ"
GenericMfg = "(スタンダード SCSI および RAID コントローラ)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI コントローラ"
[Strings.0415]
ReactOS = "Ekipa ReactOS"
SCSIClassName = "Kontrolery SCSI i RAID"
GenericMfg = "(Standardowe kontrolery SCSI i RAID)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Kontroler SCSI BusLogic"
[Strings.0416]
SCSIClassName = "Controladores SCSI e RAID"
GenericMfg = "(Controladores SCSI e RAID padrão)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
[Strings.0418]
ReactOS = "Echipa ReactOS"
SCSIClassName = "Dispozitive de control SCSI și RAID"
GenericMfg = "(dispozitiv standard de control SCSI și RAID)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Dispozitiv de control SCSI BusLogic"
[Strings.0419]
ReactOS = "Команда ReactOS"
SCSIClassName = "SCSI и RAID контроллеры"
GenericMfg = "(Стандартные SCSI и RAID контроллеры)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
[Strings.041B]
SCSIClassName = "SCSI a RAID radiče"
GenericMfg = "(Štandardné SCSI a RAID radiče)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI radič"
[Strings.041f]
ReactOS = "ReactOS Takımı"
SCSIClassName = "SCSI ve RAID Denetleyicileri"
GenericMfg = "(Ölçünlü SCSI ve RAID Denetleyicileri)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Denetleyicisi"
[Strings.0422]
ReactOS = "Команда ReactOS"
SCSIClassName = "SCSI і RAID контроллери"
GenericMfg = "(Стандартні SCSI і RAID контроллери)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
[Strings.0427]
SCSIClassName = "SCSI ir RAID valdikliai"
GenericMfg = "(Standartiniai SCSI ir RAID valdikliai)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI valdiklis"