reactos/media/inf/scsi.inf
Joachim Henze 83e1363065
[INF] More deduplication and style harmonization (#4952)
- deduplication of manufacturer strings
- at some places harmonizes the different length of separator lines within the same file, centers the words (as requested by hbelusca during review), harmonizes those lines to 74characters length each
- moving some strings that are not to be localized into the non-localization string section
- other minor formatting preferences coauthored by StasM
2022-12-28 02:26:17 +01:00

199 lines
5 KiB
INI
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

; SCSI.INF
;
; Installation file for SCSI class and SCSI hardware
;
[Version]
Signature = "$Windows NT$"
;Signature = "$ReactOS$"
LayoutFile = layout.inf
Class = SCSIAdapter
ClassGUID = {4D36E97B-E325-11CE-BFC1-08002BE10318}
Provider = %ReactOS%
DriverVer = 11/02/2007,1.1
[ClassInstall32.NT]
AddReg = SCSIClass.NT.AddReg
[SCSIClass.NT.AddReg]
HKR, , , 0, %SCSIClassName%
HKR, , Icon, 0, "-10"
;HKR, , Installer32, 0, "syssetup.dll,ScsiClassInstaller"
[DestinationDirs]
DefaultDestDir = 12
[Manufacturer]
%GenericMfg% = GenericMfg
[GenericMfg]
%GEN_SCSIADAPTER.DeviceDesc% = NO_DRV,,GEN_SCSIADAPTER
%PCI\VEN_104B&CC_0100.DeviceDesc% = BusLogic_Inst,PCI\VEN_104B&CC_0100
;--------------------------- SCSIPORT DRIVER ----------------------------
[Scsiport_CopyFiles.NT]
scsiport.sys
[Scsiport_Service_Inst]
ServiceType = 4
StartType = 0
ErrorControl = 0
ServiceBinary = %12%\scsiport.sys
LoadOrderGroup = SCSI Port
;---------------------------- NO DRIVER REQ -----------------------------
[NO_DRV]
[NO_DRV.Services]
AddService = , 0x00000002
;--------------------------- BUSLOGIC DRIVER ----------------------------
[BusLogic_Inst.NT]
CopyFiles = BusLogic_CopyFiles.NT, Scsiport_CopyFiles.NT
[BusLogic_CopyFiles.NT]
buslogic.sys
[BusLogic_Inst.NT.Services]
AddService = BusLogic, 0x00000002, BusLogic_Service_Inst
AddService = Scsiport, , Scsiport_Service_Inst
[BusLogic_Service_Inst]
ServiceType = 0
StartType = 0
ErrorControl = 0
ServiceBinary = %12%\buslogic.sys
LoadOrderGroup = SCSI Miniport
;-------------------------------- STRINGS -------------------------------
[Strings]
; Non-localizable
ReactOS = "ReactOS Project"
; Localizable
SCSIClassName = "SCSI and RAID Controllers"
GenericMfg = "(Standard SCSI and RAID controllers)"
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID Host Controller"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Controller"
[Strings.0404]
SCSIClassName = "SCSI / RAID 控制器"
GenericMfg = "(標準 SCSI / RAID 控制器)"
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID 主機控制器"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
[Strings.0405]
SCSIClassName = "SCSI a RAID řadiče"
GenericMfg = "(Standardní SCSI a RAID řadiče)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI řadič"
[Strings.0407]
SCSIClassName = "SCSI und RAID Controller"
GenericMfg = "(Standard SCSI und RAID Controller)"
[Strings.0a]
SCSIClassName = "Controladores SCSI y RAID"
GenericMfg = "(Controladores estándar SCSI y RAID)"
GEN_SCSIADAPTER.DeviceDesc = "Controlador Huésped de SCSI/RAID"
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
[Strings.040C]
SCSIClassName = "Contrôleurs SCSI et RAID"
GenericMfg = "(Contrôleur standard SCSI et RAID)"
[Strings.0411]
SCSIClassName = "SCSIおよびRAID コントローラ"
GenericMfg = "(スタンダード SCSI および RAID コントローラ)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI コントローラ"
[Strings.0415]
SCSIClassName = "Kontrolery SCSI i RAID"
GenericMfg = "(Standardowe kontrolery SCSI i RAID)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Kontroler SCSI BusLogic"
[Strings.0416]
SCSIClassName = "Controladores SCSI e RAID"
GenericMfg = "(Controladores SCSI e RAID padrão)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
[Strings.0418]
SCSIClassName = "Dispozitive de control SCSI și RAID"
GenericMfg = "(dispozitiv standard de control SCSI și RAID)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Dispozitiv de control SCSI BusLogic"
[Strings.0419]
SCSIClassName = "SCSI и RAID контроллеры"
GenericMfg = "(Стандартные SCSI и RAID контроллеры)"
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID хост-контроллер"
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
[Strings.041B]
SCSIClassName = "SCSI a RAID radiče"
GenericMfg = "(Štandardné SCSI a RAID radiče)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI radič"
[Strings.041f]
SCSIClassName = "SCSI ve RAID Denetleyicileri"
GenericMfg = "(Standart SCSI ve RAID Denetleyicileri)"
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID Ana Denetleyicisi"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI Denetleyicisi"
[Strings.0422]
SCSIClassName = "SCSI і RAID контроллери"
GenericMfg = "(Стандартні SCSI і RAID контроллери)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Контроллер BusLogic SCSI"
[Strings.0427]
SCSIClassName = "SCSI ir RAID valdikliai"
GenericMfg = "(Standartiniai SCSI ir RAID valdikliai)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI valdiklis"
[Strings.0804]
GenericMfg = "(标准 SCSI / RAID 控制器)"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"
[Strings.0816]
SCSIClassName = "Controladores SCSI e RAID"
GenericMfg = "(Controladores SCSI e RAID padrão)"
PCI\VEN_104B&CC_0100.DeviceDesc = "Controlador SCSI BusLogic"
[Strings.0C04]
SCSIClassName = "SCSI / RAID 控制器"
GenericMfg = "(標準 SCSI / RAID 控制器)"
GEN_SCSIADAPTER.DeviceDesc = "SCSI/RAID 主機控制器"
PCI\VEN_104B&CC_0100.DeviceDesc = "BusLogic SCSI 控制器"