mirror of
https://github.com/reactos/reactos.git
synced 2024-12-26 17:14:41 +00:00
[BATTC] Fix comparisons when choosing to complete the status IRP
They were reversed, which meant to immediately complete the IRP if conditions were NOT satisfied. Remove a now useless/invalid call to QueryStatus, to return the status which lead to IRP completion.
This commit is contained in:
parent
9dedcb67e9
commit
997b1797f4
1 changed files with 10 additions and 22 deletions
|
@ -112,9 +112,9 @@ BatteryClassStatusNotify(PVOID ClassData)
|
|||
|
||||
ExAcquireFastMutex(&BattClass->Mutex);
|
||||
|
||||
if (!(BattWait->PowerState & BattStatus.PowerState) ||
|
||||
(BattWait->HighCapacity > BattStatus.Capacity) ||
|
||||
(BattWait->LowCapacity < BattStatus.Capacity))
|
||||
if (BattWait->PowerState != BattStatus.PowerState ||
|
||||
BattWait->HighCapacity < BattStatus.Capacity ||
|
||||
BattWait->LowCapacity > BattStatus.Capacity)
|
||||
{
|
||||
KeSetEvent(&BattClass->WaitEvent, IO_NO_INCREMENT, FALSE);
|
||||
}
|
||||
|
@ -274,16 +274,15 @@ BatteryClassIoctl(PVOID ClassData,
|
|||
|
||||
Timeout.QuadPart = Int32x32To64(BattWait.Timeout, -1000);
|
||||
|
||||
BattStatus = Irp->AssociatedIrp.SystemBuffer;
|
||||
Status = BattClass->MiniportInfo.QueryStatus(BattClass->MiniportInfo.Context,
|
||||
BattWait.BatteryTag,
|
||||
(PBATTERY_STATUS)Irp->AssociatedIrp.SystemBuffer);
|
||||
|
||||
BattStatus = Irp->AssociatedIrp.SystemBuffer;
|
||||
BattStatus);
|
||||
|
||||
if (!NT_SUCCESS(Status) ||
|
||||
((BattWait.PowerState & BattStatus->PowerState) &&
|
||||
(BattWait.HighCapacity <= BattStatus->Capacity) &&
|
||||
(BattWait.LowCapacity >= BattStatus->Capacity)))
|
||||
(BattWait.PowerState == BattStatus->PowerState &&
|
||||
BattWait.HighCapacity >= BattStatus->Capacity &&
|
||||
BattWait.LowCapacity <= BattStatus->Capacity))
|
||||
{
|
||||
BattNotify.PowerState = BattWait.PowerState;
|
||||
BattNotify.HighCapacity = BattWait.HighCapacity;
|
||||
|
@ -304,25 +303,14 @@ BatteryClassIoctl(PVOID ClassData,
|
|||
KernelMode,
|
||||
FALSE,
|
||||
BattWait.Timeout != -1 ? &Timeout : NULL);
|
||||
if (Status == STATUS_TIMEOUT)
|
||||
Status = STATUS_SUCCESS;
|
||||
|
||||
ExAcquireFastMutex(&BattClass->Mutex);
|
||||
BattClass->Waiting = FALSE;
|
||||
ExReleaseFastMutex(&BattClass->Mutex);
|
||||
|
||||
BattClass->MiniportInfo.DisableStatusNotify(BattClass->MiniportInfo.Context);
|
||||
|
||||
if (Status == STATUS_SUCCESS)
|
||||
{
|
||||
Status = BattClass->MiniportInfo.QueryStatus(BattClass->MiniportInfo.Context,
|
||||
BattWait.BatteryTag,
|
||||
(PBATTERY_STATUS)Irp->AssociatedIrp.SystemBuffer);
|
||||
if (NT_SUCCESS(Status))
|
||||
Irp->IoStatus.Information = sizeof(ULONG);
|
||||
}
|
||||
else
|
||||
{
|
||||
Status = STATUS_NO_SUCH_DEVICE;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
|
|
Loading…